N2XSY / NA2XSY
Rated Voltage: 1.8 up to 18/30 kV. 1 core: 25-630 mm2.
SPLN 43-5 / IEC 60502.
Single core copper/aluminium conductor, XLPE insulated, with/without water blocking tape, copper wire/tape screened, PVC sheathed. Used for distribution, indoor and outdoor installation in conduit throughs or trays or in the ground with minimal physical damage. Detail
N2XSRY / NA2XSRY
Rated Voltage: 1.8 up to 18/30 kV. 1 core: 25-630 mm2.
SPLN 43-5 / IEC 60502.
Single core copper/aluminium conductor, XLPE insulated, with/without water blocking tape, copper wire/tape screened, Aluminium wire armoured, PVC sheathed. Used for underground distribution, installation direct burial in wet or dry location. Detail
N2XSEY / NA2XSEY
Rated Voltage: 1.8 up to 18/30 kV. 3 core: 25-300 mm2.
SPLN 43-5 / IEC 60502.
Multicores copper/aluminium conductor, XLPE insulated, with/without water blocking tape, copper wire/tape screened, PVC sheathed. Used for distribution, indoor and outdoor installation in conduit throughs or trays or in the ground with minimal physical damage. Detail
N2XSEYBY / NA2XSEYBY
Rated Voltage: 1.8 up to 18/30 kV. 3 core: 25-300 mm2.
SPLN 43-5 / IEC 60502.
Multicores copper/aluminium conductor, XLPE insulated, with/without water blocking tape, copper wire/tape screened,double steel tape armoured, PVC sheathed. Used for primary underground distribution, installation direct burial in wet or dry location.Detail
N2XSEFGbY / NA2XSEFGbY
Rated Voltage: 1.8 up to 18/30 kV.
SPLN 43-5 / IEC 60502.
Multicores copper/aluminium conductor, XLPE insulated, with/without water blocking tape, copper wire/tape screened, flat steel wire armoured, PVC sheathed. Used for primary underground distribution, installation direct burial in wet or dry location.Detail
NFA2XSEY
Rated Voltage: 1.8 up to 18/30 kV. 3 core: 35-300 mm2.
SPLN 43-5 / IEC 60502.
Three single core power cable, aluminium conductor, XLPE insulated, with/without water blocking tape, copper wire/tape screened, PVC sheathed. Used for indoor or outdoor distribution. Instalation in conduit through or trays, power station, industrial pants and switching stations. Detail
NFA2XSEY-T
Rated Voltage: 1.8 up to 18/30 kV. 3 core: 50-240 mm2.
SPLN 43-5 / IEC 60502.
Three single core power cable, aluminium conductor, XLPE insulated, with/without water blocking tape, copper wire/tape screened, PVC sheathed, steel wire messenger. Used for outdoor instalation, power station, industrial pants and switching stations. Detail
NYFGbY / NAYFGbY
Rated Voltage: 1.8 up to 3.6/6 kV. 3 core: 10-300 mm2.
VDE - 0271.